Posted on Tuesday January 28, 2025
Successful exploitation of these vulnerabilities could overwrite reports, including user projects.
Rockwell Automation reports the following versions of DataMosaix Private Cloud are affected:
A path traversal vulnerability exists in DataMosaix Private Cloud. By specifying the character sequence in the body of the vulnerable endpoint, it is possible to overwrite files outside of the intended directory. A threat actor with admin privileges could leverage this vulnerability to overwrite reports including user projects.
CVE-2024-11932 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:H/A:N).
A CVSS v4 score has also been calculated for CVE-2024-11932. A base score of 7.0 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:H/VA:N/SC:N/SI:N/SA:N).
DataMosaix Private Cloud utilizes SQLite, which contains a use after free vulnerability in the ALTER TABLE implementation, which was demonstrated by an ORDER BY clause that belongs to a compound SELECT statement.
CVE-2020-11656 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2020-11656. A base score of 9.3 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
Rockwell Automation reported these vulnerabilities to CISA.
Rockwell Automation has addressed these issues in version v7.11.01 and encourages users to update to the newest available version. Rockwell Automation encourages users to mitigate security risks on industrial automation control systems by implement their suggested security best practices, where possible.
For more information about this issue, please see the advisory on the Rockwell Automation security page.
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.