Posted on Tuesday May 20, 2025
Successful exploitation of this vulnerability could result in information tampering on the target workstation.
Mitsubishi Electric Iconics Digital Solutions reports that the following versions of ICONICS Product Suite and Mitsubishi Electric MC Works64 are affected:
An execution with unnecessary privileges vulnerability in the AlarmWorX64 MMX Pager agent can provide the potential for information tampering. An attacker could make an unauthorized write to arbitrary files by creating a symbolic link from a file used as a write destination by the Pager Agent service of GENESIS64 and MC Works64 to a target file. This could allow the attacker to destroy the file on a PC with GENESIS64 or MC Works64 installed, resulting in a denial-of-service (DoS) condition on the PC.
CVE-2025-0921 has been assigned to this vulnerability. A CVSS v3.1 base score of 6.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:H/A:N).
A CVSS v4 score has also been calculated for CVE-2025-0921. A base score of 8.3 has been calculated; the CVSS vector string is (AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:H.
Asher Davila and Malav Vyas from Palo Alto Networks reported this vulnerability to Mitsubishi Electric and CISA.
Mitsubishi Electric recommends that users take the following mitigations to minimize the risk of exploiting this vulnerability:
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.